LOAD CHART - INVERTER & HOME UPS |
|
|
|
|
|
Rating |
350VA |
650VA |
850VA |
1550VA |
1850VA |
3000VA |
3500VA |
Option |
I |
II |
I |
II |
I |
II |
I |
II |
1 |
II |
I |
II |
I |
II |
Fan |
1 |
1 |
3 |
1 |
4 |
2 |
7 |
2 |
10 |
3 |
13 |
4 |
18 |
7 |
Tube - Light |
2 |
1 |
3 |
1 |
4 |
2 |
8 |
4 |
12 |
5 |
15 |
5 |
18 |
7 |
Computer |
x |
x |
x |
1 |
x |
1 |
x |
2 |
x |
3 |
x |
5 |
2 |
6 |
T.V (Up to 21") |
x |
1 |
1 |
x |
1 |
x |
1 |
1 |
1 |
1 |
2 |
x |
1 |
1 |
Battery
DC Volt |
12
V |
12
V |
12
V |
24
V |
48 V |
48 V |
48 V |
|
|
|
|
|
|
|
|
|
TECHNICAL
SPECIFICATIONS |
Rating |
300 VA
to 3000 VA |
AC Input |
100V to 285V ±
10V AC (Inverter Mode) |
175V to 270V
(Home UPS Mode) |
Output Voltage
Range |
200-250V AC
(backup mode) |
Output
Frequency |
50 ± 0.1 Hz |
Output Waveform |
Modified Sine
Wave |
Transfer Time |
@ 70m Sec.
(Inverter mode) |
@ 15-15m Sec.
(Home UPS mode) |
Display |
LED (Mains,
Inverter, charging, overload, battery low), LCD (16X2 lines) |
Battery Charger
Range |
125 to 275 V AC |
Battery Charging
Current |
2 Amp. to 15
Amp. DC. |
Battery Boost
Voltage |
13.8 / 14.2
Volts±0.1 V. |
Battery Low
cut-off |
9.6 Volts ± 0.2
V. |
Overload |
Trips after 10
seconds, Four retries. |
Environmental |
Operating temperature 00 C to 500 C Humidity Max 95%, Non- Condensing |
|
|
|
|
|
|
|
|
|